This Human α-GST ELISA Kit was designed for the quantitative measurement of Human α-GST protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 0.156 ng/mL-10 ng/mL and the sensitivity is 0.039 ng/mL.
别名
Glutathione S alkyltransferase A1 ELISA Kit; Glutathione S aryltransferase A1 ELISA Kit; Glutathione S transferase 2 ELISA Kit; Glutathione S transferase A1 ELISA Kit; Glutathione S transferase alpha 1 ELISA Kit; Glutathione S transferase Ha subunit 1 ELISA Kit; Glutathione S-transferase A1 ELISA Kit; GST class-alpha member 1 ELISA Kit; GST epsilon ELISA Kit; GST HA subunit 1 ELISA Kit; GST; class alpha; 1 ELISA Kit; GST-epsilon ELISA Kit; GST2 ELISA Kit; GSTA1 1 ELISA Kit; GSTA1 ELISA Kit; GSTA1-1 ELISA Kit; GSTA1_HUMAN ELISA Kit; GTH1 ELISA Kit; HA subunit 1 ELISA Kit; MGC131939 ELISA Kit; OTTHUMP00000016611 ELISA Kit; S (hydroxyalkyl)glutathione lyase A1 ELISA Kit
缩写
α-GST
Uniprot No
P08263
灵敏度
0.039 ng/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Metabolism
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human α-GST in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| Sample | Serum(n=4) | |
| 1:1 | Average % | 102 | |
| Range % | 98-109 | |
| 1:2 | Average % | 86 | |
| Range % | 81-90 | |
| 1:4 | Average % | 93 | |
| Range % | 89-98 | |
| 1:8 | Average % | 90 | |
| Range % | 85-94 | |
回收率
| The recovery of human α-GST spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 95 | 90-100 | |
| EDTA plasma (n=4) | 88 | 84-92 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| ng/ml | OD1 | OD2 | Average | Corrected | | | 10 | 2.716 | 2.629 | 2.673 | 2.559 | | | 5 | 2.071 | 2.002 | 2.037 | 1.923 | | | 2.5 | 1.482 | 1.567 | 1.525 | 1.411 | | | 1.25 | 0.904 | 0.961 | 0.933 | 0.819 | | | 0.625 | 0.589 | 0.623 | 0.606 | 0.492 | | | 0.312 | 0.365 | 0.384 | 0.375 | 0.261 | | | 0.156 | 0.259 | 0.263 | 0.261 | 0.147 | | | 0 | 0.113 | 0.115 | 0.114 | | |
|
货期
3-5 working days