产品描述
This Human PDGFC ELISA Kit was designed for the quantitative measurement of Human PDGFC protein in serum, urine, cell culture supernates, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 6.25 pg/mL-400 pg/mL and the sensitivity is 1.56 pg/mL.
别名
Fallotein ELISA Kit; hSCDGF ELISA Kit; PDGF-C ELISA Kit; PDGFC ELISA Kit; PDGFC latent form ELISA Kit; PDGFC receptor-binding form ELISA Kit; PDGFC_HUMAN ELISA Kit; Platelet derived growth factor C ELISA Kit; Platelet-derived growth factor C; receptor-binding form ELISA Kit; SCDGF ELISA Kit; Secretory growth factor like protein ELISA Kit; Secretory growth factor like protein fallotein ELISA Kit; Spinal cord derived growth factor ELISA Kit; Spinal cord-derived growth factor ELISA Kit; VEGF E ELISA Kit; VEGF-E ELISA Kit
缩写
PDGFC
Uniprot No
Q9NRA1
灵敏度
1.56 pg/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Cardiovascular
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human VEGF-E in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| | Sample | Serum(n=4) | |
| 1:1 | Average % | 85 | |
| Range % | 80-90 | |
| 1:2 | Average % | 96 | |
| Range % | 90-100 | |
| 1:4 | Average % | 98 | |
| Range % | 91-105 | |
| 1:8 | Average % | 90 | |
| Range % | 82-98 | |
回收率
| The recovery of human VEGF-E spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 91 | 83-98 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| pg/ml | OD1 | OD2 | Average | Corrected | | | 400 | 2.806 | 2.712 | 2.759 | 2.659 | | | 200 | 2.012 | 2.066 | 2.039 | 1.939 | | | 100 | 1.473 | 1.384 | 1.429 | 1.329 | | | 50 | 0.958 | 0.893 | 0.926 | 0.826 | | | 25 | 0.494 | 0.473 | 0.484 | 0.384 | | | 12.5 | 0.321 | 0.301 | 0.311 | 0.211 | | | 6.25 | 0.254 | 0.249 | 0.252 | 0.152 | | | 0 | 0.102 | 0.097 | 0.100 | | |
|
货期
3-5 working days