产品描述
This Human sCD146 ELISA Kit was designed for the quantitative measurement of Human sCD146 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 1.25 ng/mL-80 ng/mL and the sensitivity is 0.31 ng/mL.
别名
A32 antigen ELISA Kit; CD 146 ELISA Kit; CD146 ELISA Kit; CD146 antigen ELISA Kit; Cell surface glycoprotein MUC18 ELISA Kit; Cell surface glycoprotein P1H12 ELISA Kit; Gicerin ELISA Kit; Mcam ELISA Kit; Melanoma adhesion molecule ELISA Kit; Melanoma associated antigen A32 ELISA Kit; Melanoma associated antigen MUC18 ELISA Kit; Melanoma associated glycoprotein MUC18 ELISA Kit; Melanoma cell adhesion molecule ELISA Kit; Melanoma-associated antigen A32 ELISA Kit; Melanoma-associated antigen MUC18 ELISA Kit; MelCAM ELISA Kit; MUC 18 ELISA Kit; MUC18 ELISA Kit; MUC18_HUMAN ELISA Kit; S endo 1 ELISA Kit; S endo 1 endothelial associated antigen ELISA Kit; S-endo 1 endothelial-associated antigen ELISA Kit
缩写
sCD146
Uniprot No
P43121
灵敏度
0.31 ng/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Others
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human sCD146 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| Sample | Serum(n=4) | |
| 1:5 | Average % | 85 | |
| Range % | 81-90 | |
| 1:10 | Average % | 96 | |
| Range % | 93-99 | |
| 1:20 | Average % | 87 | |
| Range % | 83-90 | |
| 1:40 | Average % | 104 | |
| Range % | 101-104 | |
回收率
| The recovery of human sCD146 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 96 | 93-99 | |
| EDTA plasma (n=4) | 98 | 95-101 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| ng/ml | OD1 | OD2 | Average | Corrected | | | 80 | 2.952 | 2.968 | 2.960 | 2.777 | | | 40 | 2.383 | 2.375 | 2.379 | 2.196 | | | 20 | 1.615 | 1.646 | 1.631 | 1.448 | | | 10 | 0.972 | 0.999 | 0.986 | 0.803 | | | 5 | 0.595 | 0.578 | 0.587 | 0.404 | | | 2.5 | 0.437 | 0.468 | 0.453 | 0.270 | | | 1.25 | 0.364 | 0.357 | 0.361 | 0.178 | | | 0 | 0.182 | 0.184 | 0.183 | | |
|
货期
3-5 working days