产品描述
This Human TSG101 ELISA Kit was designed for the quantitative measurement of Human TSG101 protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 23.44 pg/mL-1500 pg/mL and the sensitivity is 5.86 pg/mL.
别名
ESCRT I complex subunit TSG101 ELISA Kit; ESCRT-I complex subunit TSG101 ELISA Kit; TS101_HUMAN ELISA Kit; TSG 10 ELISA Kit; TSG 101 ELISA Kit; TSG10 ELISA Kit; Tsg101 ELISA Kit; Tumor susceptibility 101 ELISA Kit; Tumor susceptibility gene 10 ELISA Kit; Tumor susceptibility gene 101 ELISA Kit; Tumor susceptibility gene 101 protein ELISA Kit; Tumor susceptibility protein ELISA Kit; Tumor susceptibility protein isoform 3 ELISA Kit; VPS 23 ELISA Kit; VPS23 ELISA Kit
缩写
TSG101
Uniprot No
Q99816
灵敏度
5.86 pg/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Cancer
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human TSG101 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | |
| | Sample | Serum(n=4) | | |
| 1:1 | Average % | 98 | | |
| Range % | 92-104 | | |
| 1:2 | Average % | 108 | | |
| Range % | 103-112 | | |
| 1:4 | Average % | 94 | | |
| Range % | 90-98 | | |
| 1:8 | Average % | 89 | | |
| Range % | 86-95 | | |
回收率
| The recovery of human TSG101 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | |
|
| Sample Type | Average % Recovery | Range | | |
| Serum (n=5) | 102 | 99-106 | | |
| EDTA plasma (n=4) | 94 | 90-98 | | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | |
|
| pg/ml | OD1 | OD2 | Average | Corrected | | | | 1500 | 1.872 | 1.921 | 1.897 | 1.787 | | | | 750 | 1.322 | 1.388 | 1.355 | 1.245 | | | | 375 | 0.954 | 0.902 | 0.928 | 0.818 | | | | 187.5 | 0.608 | 0.622 | 0.615 | 0.505 | | | | 93.75 | 0.417 | 0.412 | 0.415 | 0.305 | | | | 46.88 | 0.289 | 0.287 | 0.288 | 0.178 | | | | 23.44 | 0.230 | 0.244 | 0.237 | 0.127 | | | | 0 | 0.109 | 0.111 | 0.110 | | | | | | . | | | | | |
|
货期
3-5 working days