产品描述
This Human PPARA ELISA Kit was designed for the quantitative measurement of Human PPARA protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 78 pg/mL-5000 pg/mL and the sensitivity is 19.5 pg/mL.
别名
hPPAR ELISA Kit; MGC2237 ELISA Kit; MGC2452 ELISA Kit; NR1C1 ELISA Kit; Nuclear receptor subfamily 1 group C member 1 ELISA Kit; OTTHUMP00000197740 ELISA Kit; OTTHUMP00000197741 ELISA Kit; Peroxisome proliferative activated receptor alpha ELISA Kit; Peroxisome proliferator activated receptor alpha ELISA Kit; Peroxisome proliferator-activated receptor alpha ELISA Kit; PPAR ELISA Kit; PPAR-alpha ELISA Kit; ppara ELISA Kit; PPARA_HUMAN ELISA Kit; PPARalpha ELISA Kit
缩写
PPARA
Uniprot No
Q07869
灵敏度
19.5 pg/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Metabolism
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human PPAR-α in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| Sample | Serum(n=4) | |
| 1:1 | Average % | 91 | |
| Range % | 86-95 | |
| 1:2 | Average % | 102 | |
| Range % | 97-107 | |
| 1:4 | Average % | 91 | |
| Range % | 85-97 | |
| 1:8 | Average % | 97 | |
| Range % | 91-103 | |
回收率
| The recovery of human PPAR-α spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 95 | 89-98 | |
| EDTA plasma (n=4) | 98 | 90-101 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| pg/ml | OD1 | OD2 | Average | Corrected | | | 5000 | 2.806 | 2.869 | 2.838 | 2.744 | | | 2500 | 2.070 | 2.098 | 2.084 | 1.990 | | | 1250 | 1.137 | 1.168 | 1.153 | 1.059 | | | 625 | 0.598 | 0.578 | 0.588 | 0.494 | | | 312 | 0.315 | 0.321 | 0.318 | 0.224 | | | 156 | 0.219 | 0.229 | 0.224 | 0.130 | | | 78 | 0.157 | 0.159 | 0.158 | 0.064 | | | 0 | 0.095 | 0.093 | 0.094 | | |
|
货期
3-5 working days