产品描述
This Human PDIA3 ELISA Kit was designed for the quantitative measurement of Human PDIA3 protein in serum, plasma, cell culture supernates. It is a Sandwich ELISA kit, its detection range is 1.25 ng/mL-80 ng/mL and the sensitivity is 0.31 ng/mL.
别名
58 kDa glucose regulated protein ELISA Kit; 58 kDa glucose-regulated protein ELISA Kit; 58 kDa microsomal protein ELISA Kit; Disulfide isomerase ER 60 ELISA Kit; Disulfide isomerase ER-60 ELISA Kit; Endoplasmic reticulum resident protein 57 ELISA Kit; Endoplasmic reticulum resident protein 60 ELISA Kit; ER p57 ELISA Kit; ER protein 57 ELISA Kit; ER protein 60 ELISA Kit; ERp 57 ELISA Kit; ERp57 ELISA Kit; ERp60 ELISA Kit; ERp61 ELISA Kit; Glucose Regulated Protein 58 Kd ELISA Kit; GRP 57 ELISA Kit; GRP 58 ELISA Kit; GRP57 ELISA Kit; HsT17083 ELISA Kit; p58 ELISA Kit; PDIA 3 ELISA Kit; PDIA3 ELISA Kit; PDIA3_HUMAN ELISA Kit; Phospholipase C alpha ELISA Kit; PI PLC ELISA Kit; Protein disulfide isomerase A3 ELISA Kit; Protein disulfide isomerase family A member 3 ELISA Kit; Protein disulfide-isomerase A3 ELISA Kit
缩写
PDIA3
Uniprot No
P30101
灵敏度
0.31 ng/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Others
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human PDIA3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| Sample | Serum(n=4) | |
| 1:1 | Average % | 94 | |
| Range % | 87-98 | |
| 1:2 | Average % | 104 | |
| Range % | 98-108 | |
| 1:4 | Average % | 92 | |
| Range % | 85-96 | |
| 1:8 | Average % | 97 | |
| Range % | 91-102 | |
回收率
| The recovery of hhuman PDIA3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 90 | 85-94 | |
| EDTA plasma (n=4) | 95 | 90-99 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| ng/ml | OD1 | OD2 | Average | Corrected | | | 80 | 2.576 | 2.521 | 2.549 | 2.398 | | | 40 | 2.156 | 2.054 | 2.105 | 1.954 | | | 20 | 1.487 | 1.445 | 1.466 | 1.315 | | | 10 | 0.766 | 0.777 | 0.772 | 0.621 | | | 5 | 0.492 | 0.468 | 0.480 | 0.329 | | | 2.5 | 0.374 | 0.369 | 0.372 | 0.221 | | | 1.25 | 0.255 | 0.248 | 0.252 | 0.101 | | | 0 | 0.153 | 0.149 | 0.151 | | |
|
货期
3-5 working days