产品描述
This Human SIRT3 ELISA Kit was designed for the quantitative measurement of Human SIRT3 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 15.6 pg/mL-1000 pg/mL and the sensitivity is 3.9 pg/mL .
别名
hSIRT 3 ELISA Kit; hSIRT3 ELISA Kit; Mitochondrial nicotinamide adenine dinucleotide dependent deacetylase ELISA Kit; NAD dependent deacetylase sirtuin 3 mitochondrial ELISA Kit; NAD-dependent protein deacetylase sirtuin-3, mitochondrial ELISA Kit; Regulatory protein SIR2 homolog 3 ELISA Kit; Silent mating type information regulation 2 S.cerevisiae homolog 3 ELISA Kit; Sir 2 like 3 ELISA Kit; SIR 2 like protein 3 ELISA Kit; SIR 3 ELISA Kit; SIR2 L3 ELISA Kit; Sir2 like 3 ELISA Kit; SIR2 like protein 3 ELISA Kit; SIR2-like protein 3 ELISA Kit; SIR2L3 ELISA Kit; SIR3_HUMAN ELISA Kit; SIRT 3 ELISA Kit; SIRT3 ELISA Kit; Sirtuin 3 ELISA Kit; Sirtuin silent mating type information regulation 2 homolog 3 (S. cerevisiae) ELISA Kit; Sirtuin type 3 ELISA Kit; Sirtuin3 ELISA Kit
缩写
SIRT3
Uniprot No
Q9NTG7
灵敏度
3.9 pg/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Epigenetics and Nuclear Signaling
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human SIRT3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| | Sample | Serum(n=4) | |
| 1:1 | Average % | 89 | |
| Range % | 82-95 | |
| 1:2 | Average % | 92 | |
| Range % | 86-99 | |
| 1:4 | Average % | 98 | |
| Range % | 90-105 | |
| 1:8 | Average % | 93 | |
| Range % | 88-100 | |
回收率
| The recovery of human SIRT3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 94 | 90-103 | |
| EDTA plasma (n=4) | 90 | 84-97 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| pg/ml | OD1 | OD2 | Average | Corrected | | | 1000 | 2.743 | 2.612 | 2.678 | 2.540 | | | 500 | 2.312 | 2.156 | 2.234 | 2.096 | | | 250 | 1.713 | 1.686 | 1.700 | 1.562 | | | 125 | 1.021 | 1.009 | 1.015 | 0.877 | | | 62.5 | 0.514 | 0.557 | 0.536 | 0.398 | | | 31.2 | 0.321 | 0.301 | 0.311 | 0.173 | | | 15.6 | 0.203 | 0.196 | 0.200 | 0.062 | | | 0 | 0.139 | 0.137 | 0.138 | | |
|
货期
3-5 working days