产品描述
This Human HMGCR ELISA Kit was designed for the quantitative measurement of Human HMGCR protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 0.78 ng/mL- 50 ng/mL and the sensitivity is 0.195 ng/mL .
别名
3 hydroxy 3 methylglutaryl CoA reductase ELISA Kit; 3 hydroxy 3 methylglutaryl Coenzyme A reductase ELISA Kit; 3 hydroxymethylglutaryl CoA reductase ELISA Kit; 3-hydroxy-3-methylglutaryl CoA reductase (NADPH) ELISA Kit; 3-hydroxy-3-methylglutaryl-coenzyme A reductase ELISA Kit; 3H3M ELISA Kit; HMDH_HUMAN ELISA Kit; HMG CoA reductase ELISA Kit; HMG CoAR ELISA Kit; HMG-CoA reductase ELISA Kit; Hmgcr ELISA Kit; Hydroxymethylglutaryl CoA reductase ELISA Kit; LDLCQ3 ELISA Kit; MGC103269 ELISA Kit; Red ELISA Kit
缩写
HMGCR
Uniprot No
P04035
灵敏度
0.195 ng/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Metabolism
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human HMG-CoAR in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| | Sample | Serum(n=4) | |
| 1:1 | Average % | 95 | |
| Range % | 92-100 | |
| 1:2 | Average % | 91 | |
| Range % | 82-96 | |
| 1:4 | Average % | 95 | |
| Range % | 87-100 | |
| 1:8 | Average % | 87 | |
| Range % | 82-98 | |
回收率
| The recovery of HMG-CoAR spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 96 | 91-101 | |
| EDTA plasma (n=4) | 90 | 82-97 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| ng/ml | OD1 | OD2 | Average | Corrected | | | 50 | 2.325 | 2.450 | 2.388 | 2.271 | | | 25 | 2.050 | 2.174 | 2.112 | 1.995 | | | 12.5 | 1.476 | 1.563 | 1.520 | 1.403 | | | 6.25 | 0.659 | 0.697 | 0.678 | 0.561 | | | 3.12 | 0.245 | 0.261 | 0.253 | 0.136 | | | 1.56 | 0.192 | 0.186 | 0.189 | 0.072 | | | 0.78 | 0.151 | 0.140 | 0.146 | 0.029 | | | 0 | 0.120 | 0.113 | 0.117 | | |
|
货期
3-5 working days