产品描述
This Human Coagulation factor V (F5) ELISA Kit was designed for the quantitative measurement of Human Coagulation factor V (F5) protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 3.12 ng/mL-200 ng/mL and the sensitivity is 0.78 ng/mL.
别名
Activated protein C cofactor ELISA Kit; APC cofactor ELISA Kit; coagulation factor V (proaccelerin; labile factor) ELISA Kit; Coagulation factor V ELISA Kit; coagulation factor V jinjiang A2 domain ELISA Kit; Coagulation factor V light chain ELISA Kit; F5 ELISA Kit; FA5_HUMAN ELISA Kit; Factor V Leiden ELISA Kit; FactorV ELISA Kit; FVL ELISA Kit; Labile factor ELISA Kit; PCCF ELISA Kit; Proaccelerin ELISA Kit; proaccelerin; labile factor ELISA Kit; Protein C cofactor ELISA Kit; RPRGL1 ELISA Kit; THPH2 ELISA Kit
缩写
F5
Uniprot No
P12259
灵敏度
0.78 ng/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Blood Coagulation
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human FⅤ in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. | |
| | Sample | Serum(n=4) | | |
| 1:1000 | Average % | 85 | | |
| Range % | 80-89 | | |
| 1:2000 | Average % | 94 | | |
| Range % | 90-98 | | |
| 1:4000 | Average % | 96 | | |
| Range % | 92-100 | | |
| 1:8000 | Average % | 103 | | |
| Range % | 99-107 | | |
回收率
| The recovery of human FⅤ spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. | |
|
| Sample Type | Average % Recovery | Range | | |
| Serum (n=5) | 88 | 84-92 | | |
| EDTA plasma (n=4) | 93 | 89-100 | | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | |
|
| ng/ml | OD1 | OD2 | Average | Corrected | | | | 200 | 2.444 | 2.536 | 2.490 | 2.360 | | | | 100 | 2.186 | 2.099 | 2.143 | 2.013 | | | | 50 | 1.754 | 1.682 | 1.718 | 1.588 | | | | 25 | 1.156 | 1.104 | 1.130 | 1.000 | | | | 12.5 | 0.668 | 0.715 | 0.692 | 0.562 | | | | 6.25 | 0.403 | 0.387 | 0.395 | 0.265 | | | | 3.12 | 0.289 | 0.284 | 0.287 | 0.157 | | | | 0 | 0.132 | 0.128 | 0.130 | | | |
|
货期
3-5 working days