产品描述
This Human FGF8 ELISA Kit was designed for the quantitative measurement of Human FGF8 protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 15.6 pg/mL-1000 pg/mL and the sensitivity is 3.9 pg/mL.
别名
AIGF ELISA Kit; Androgen induced growth factor ELISA Kit; Androgen-induced growth factor ELISA Kit; FGF 8 ELISA Kit; FGF-8 ELISA Kit; FGF-8b ELISA Kit; FGF8 ELISA Kit; FGF8_HUMAN ELISA Kit; Fibroblast growth factor 8 (androgen induced) ELISA Kit; Fibroblast growth factor 8 ELISA Kit; Fibroblast growth factor 8 precursor ELISA Kit; HBGF 8 ELISA Kit; HBGF-8 ELISA Kit; HBGF8 ELISA Kit; Heparin-binding growth factor 8 ELISA Kit; HH6 ELISA Kit; KAL6 ELISA Kit
缩写
FGF8
Uniprot No
P55075
灵敏度
3.9 pg/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Signal Transduction
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human FGF8 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| Sample | Serum(n=4) | |
| 1:1 | Average % | 91 | |
| Range % | 86-95 | |
| 1:2 | Average % | 102 | |
| Range % | 97-107 | |
| 1:4 | Average % | 91 | |
| Range % | 85-97 | |
| 1:8 | Average % | 97 | |
| Range % | 91-103 | |
回收率
| The recovery of human FGF8 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 95 | 89-98 | |
| EDTA plasma (n=4) | 97 | 90-100 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| pg/ml | OD1 | OD2 | Average | Corrected | | | 1000 | 2.455 | 2.498 | 2.477 | 2.290 | | | 500 | 1.872 | 1.932 | 1.902 | 1.715 | | | 250 | 1.213 | 1.236 | 1.225 | 1.038 | | | 125 | 0.687 | 0.699 | 0.693 | 0.506 | | | 62.5 | 0.499 | 0.484 | 0.492 | 0.305 | | | 31.2 | 0.379 | 0.398 | 0.389 | 0.202 | | | 15.6 | 0.277 | 0.287 | 0.282 | 0.095 | | | 0 | 0.188 | 0.186 | 0.187 | | |
|
货期
3-5 working days