This Human Bcl-xl ELISA Kit was designed for the quantitative measurement of Human Bcl-xl protein in serum, plasma, cell culture supernates. It is a Sandwich ELISA kit, its detection range is 0.156 ng/mL-10 ng/mL and the sensitivity is 0.039 ng/mL.
别名
AI325008 ELISA Kit; BAD ELISA Kit; BAD_HUMAN ELISA Kit; BBC 2 ELISA Kit; BBC2 ELISA Kit; BBC6 ELISA Kit; Bcl 2 Antagonist of Cell Death ELISA Kit; Bcl 2 Binding Component 6 ELISA Kit; BCL X / BCL 2 Binding Protein ELISA Kit; BCL X Binding Protein ELISA Kit; Bcl XL/Bcl 2 Associated Death Promoter ELISA Kit; Bcl-2-binding component 6 ELISA Kit; Bcl-2-like protein 8 ELISA Kit; Bcl-XL/Bcl-2-associated death promoter ELISA Kit; Bcl2 antagonist of cell death ELISA Kit; BCL2 antagonist of cell death protein ELISA Kit; BCL2 associated agonist of cell death ELISA Kit; Bcl2 Associated Death Promoter ELISA Kit; BCL2 binding component 6 ELISA Kit; BCL2 binding protein ELISA Kit; Bcl2 Like 8 Protein ELISA Kit; Bcl2-L-8 ELISA Kit; BCL2L8 ELISA Kit; Proapoptotic BH3 Only Protein ELISA Kit
缩写
Bcl-xl
Uniprot No
Q92934
灵敏度
0.039 ng/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Cancer
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human Bcl-xl in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| Sample | Serum(n=4) | |
| 1:1 | Average % | 84 | |
| Range % | 80-89 | |
| 1:2 | Average % | 97 | |
| Range % | 92-101 | |
| 1:4 | Average % | 105 | |
| Range % | 100-110 | |
| 1:8 | Average % | 93 | |
| Range % | 86-98 | |
回收率
| The recovery of human Bcl-xl spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 95 | 89-99 | |
| EDTA plasma (n=4) | 90 | 85-94 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| ng/ml | OD1 | OD2 | Average | Corrected | | | 10 | 2.415 | 2.352 | 2.384 | 2.190 | | | 5 | 1.934 | 1.876 | 1.905 | 1.711 | | | 2.5 | 1.405 | 1.504 | 1.455 | 1.261 | | | 1.25 | 0.902 | 0.939 | 0.921 | 0.727 | | | 0.625 | 0.544 | 0.524 | 0.534 | 0.340 | | | 0.312 | 0.378 | 0.359 | 0.369 | 0.175 | | | 0.156 | 0.291 | 0.309 | 0.300 | 0.106 | | | 0 | 0.191 | 0.197 | 0.194 | | |
|
货期