产品描述
The ELISA Kit is designed to measure human BACE1 levels in samples, including serum, plasma, or tissue homogenates. It uses the sandwich enzyme immunoassay technique in combination with the enzyme-substrate chromogenic reaction to quantify the analyte in the sample. The color develops positively to the amount of BACE1 in samples. The color intensity is measured at 450 nm via a microplate reader.
BACE1 is an aspartic protease that catalyzes the rate-limiting, initial cleavage at the β site of amyloid precursor protein (APP) and is followed by sequential intra-membrane processing at multiple sites by γ-secretase in the production of amyloid-β (Aβ). It is widely expressed in the brain, particularly in neurons, oligodendrocytes, and astrocytes, with particular abundance in various neuronal cell types. Inhibition of BACE1 proteolytic activity has been demonstrated to reduce Aβ generation and amyloid deposition, and thus specific inhibition of BACE1 by small molecules is a current focus for Alzheimer's disease therapy. In addition to the amyloidogenic pathway, BACE1 is involved in synaptic plasticity and synaptic homeostasis.
别名
BACE1; BACE; KIAA1149; Beta-secretase 1; Aspartyl protease 2; ASP2; Asp 2; Beta-site amyloid precursor protein cleaving enzyme 1; Beta-site APP cleaving enzyme 1; Memapsin-2; Membrane-associated aspartic protease 2
缩写
BACE1
Uniprot No
P56817
灵敏度
0.78 pg/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Cell Biology
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% |
|
|
|
| Three samples of known concentration were tested twenty times on one plate to assess. |
|
| Inter-assay Precision (Precision between assays): CV%<10% |
|
|
|
| Three samples of known concentration were tested in twenty assays to assess. |
|
|
| |
|
|
|
|
|
|
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human BACE1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| |
Sample |
Serum(n=4) |
|
| 1:100 |
Average % |
90 |
|
| Range % |
82-97 |
|
| 1:200 |
Average % |
95 |
|
| Range % |
90-100 |
|
| 1:400 |
Average % |
92 |
|
| Range % |
88-105 |
|
| 1:800 |
Average % |
96 |
|
| Range % |
85-101 |
|
回收率
| The recovery of human BACE1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
| Sample Type |
Average % Recovery |
Range |
|
| Serum (n=5) |
91 |
80-100 |
|
| EDTA plasma (n=4) |
98 |
92-105 |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
| pg/ml |
OD1 |
OD2 |
Average |
Corrected |
|
| 200 |
2.168 |
2.052 |
2.110 |
2.017 |
|
| 100 |
1.907 |
1.860 |
1.884 |
1.791 |
|
| 50 |
1.595 |
1.494 |
1.545 |
1.452 |
|
| 25 |
1.324 |
1.239 |
1.282 |
1.189 |
|
| 12.5 |
0.906 |
0.874 |
0.890 |
0.797 |
|
| 6.25 |
0.429 |
0.409 |
0.419 |
0.326 |
|
| 3.12 |
0.277 |
0.269 |
0.273 |
0.180 |
|
| 0 |
0.096 |
0.090 |
0.093 |
|
|
|
货期
3-5 working days