产品描述
This Human CA2 ELISA Kit was designed for the quantitative measurement of Human CA2 protein in serum, plasma, tissue homogenates. It is a Sandwich ELISA kit, its detection range is 0.312 ng/mL-20 ng/mL and the sensitivity is 0.078 ng/mL.
别名
CA 2 ELISA Kit; CA II ELISA Kit; CA-II ELISA Kit; Ca2 ELISA Kit; CAC ELISA Kit; CAH2_HUMAN ELISA Kit; CAII ELISA Kit; Car 2 ELISA Kit; Car2 ELISA Kit; Carbonate dehydratase II ELISA Kit; Carbonic anhydrase 2 ELISA Kit; Carbonic anhydrase B ELISA Kit; Carbonic anhydrase C ELISA Kit; Carbonic anhydrase C; formerly ELISA Kit; Carbonic anhydrase II ELISA Kit; Carbonic dehydratase ELISA Kit; epididymis luminal protein 76 ELISA Kit; Epididymis secretory protein Li 282 ELISA Kit; HEL-76 ELISA Kit; HEL-S-282 ELISA Kit
缩写
CA2
Uniprot No
P00918
灵敏度
0.078 ng/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Cell Biology
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% |
|
|
|
| Three samples of known concentration were tested twenty times on one plate to assess. |
|
| Inter-assay Precision (Precision between assays): CV%<10% |
|
|
|
| Three samples of known concentration were tested in twenty assays to assess. |
|
|
| |
|
|
|
|
|
|
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human CA-2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| |
Sample |
Serum(n=4) |
|
| 1:1 |
Average % |
99 |
|
| Range % |
92-103 |
|
| 1:2 |
Average % |
102 |
|
| Range % |
95-105 |
|
| 1:4 |
Average % |
91 |
|
| Range % |
85-94 |
|
| 1:8 |
Average % |
88 |
|
| Range % |
84-92 |
|
回收率
| The recovery of human CA-2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
| Sample Type |
Average % Recovery |
Range |
|
| Serum (n=5) |
90 |
85-94 |
|
| EDTA plasma (n=4) |
91 |
82-94 |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
| ng/ml |
OD1 |
OD2 |
Average |
Corrected |
|
| 20 |
2.700 |
2.542 |
2.621 |
2.502 |
|
| 10 |
2.191 |
2.113 |
2.152 |
2.033 |
|
| 5 |
1.374 |
1.351 |
1.363 |
1.244 |
|
| 2.5 |
0.765 |
0.754 |
0.760 |
0.641 |
|
| 1.25 |
0.373 |
0.379 |
0.376 |
0.257 |
|
| 0.625 |
0.310 |
0.323 |
0.317 |
0.198 |
|
| 0.312 |
0.215 |
0.211 |
0.213 |
0.094 |
|
| 0 |
0.120 |
0.118 |
0.119 |
|
|
|
货期
3-5 working days