产品描述
This Human CD274 ELISA Kit was designed for the quantitative measurement of Human CD274 protein in serum, plasma, tissue homogenates, cell lysates. It is a Sandwich ELISA kit, its detection range is 15.6 pg/mL-1000 pg/mL and the sensitivity is 3.9 pg/mL .
别名
B7 H ELISA Kit; B7 H1 ELISA Kit; B7 homolog 1 ELISA Kit; B7-H1 ELISA Kit; B7H ELISA Kit; B7H1 ELISA Kit; CD 274 ELISA Kit; CD274 ELISA Kit; CD274 antigen ELISA Kit; CD274 molecule ELISA Kit; MGC142294 ELISA Kit; MGC142296 ELISA Kit; OTTHUMP00000021029 ELISA Kit; PD L1 ELISA Kit; PD-L1 ELISA Kit; PD1L1_HUMAN ELISA Kit; PDCD1 ligand 1 ELISA Kit; PDCD1L1 ELISA Kit; PDCD1LG1 ELISA Kit; PDL 1 ELISA Kit; PDL1 ELISA Kit; Programmed cell death 1 ligand 1 ELISA Kit; Programmed death ligand 1 ELISA Kit; RGD1566211 ELISA Kit
缩写
CD274
Uniprot No
Q9NZQ7
灵敏度
3.9 pg/mL
反应时间
1-5h
样本体积
50-100ul
检测波长
450 nm
研究领域
Others
测定原理
quantitative
精密度
| Intra-assay Precision (Precision within an assay): CV%<8% | | | |
| Three samples of known concentration were tested twenty times on one plate to assess. | |
| Inter-assay Precision (Precision between assays): CV%<10% | | | |
| Three samples of known concentration were tested in twenty assays to assess. | | |
| | | | | | | |
线性度
| To assess the linearity of the assay, samples were spiked with high concentrations of human PD-L1/CD274 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| | Sample | Serum(n=4) | |
| 1:1 | Average % | 90 | |
| Range % | 80-101 | |
| 1:2 | Average % | 95 | |
| Range % | 91-105 | |
| 1:4 | Average % | 98 | |
| Range % | 90-107 | |
| 1:8 | Average % | 95 | |
| Range % | 85-100 | |
回收率
| The recovery of human PD-L1/CD274 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| Sample Type | Average % Recovery | Range | |
| Serum (n=5) | 96 | 89-104 | |
| EDTA plasma (n=4) | 95 | 90-107 | |
| | | | | | | |
| | | | | | | |
标准曲线
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| pg/ml | OD1 | OD2 | Average | Corrected | | | 1000 | 2.274 | 2.174 | 2.224 | 1.965 | | | 500 | 1.940 | 1.854 | 1.897 | 1.638 | | | 250 | 1.450 | 1.355 | 1.403 | 1.144 | | | 125 | 0.927 | 0.955 | 0.941 | 0.682 | | | 62.5 | 0.570 | 0.580 | 0.575 | 0.316 | | | 31.2 | 0.422 | 0.417 | 0.420 | 0.161 | | | 15.6 | 0.352 | 0.341 | 0.347 | 0.088 | | | 0 | 0.253 | 0.265 | 0.259 | | |
|
货期
3-5 working days